According to the CORE requirements and 270 TR3, only a single patient request may be sent within a payload/file.

What is the recommended way to reject incoming data when:
1. payload/file has multiple interchanges. Should second and so on interchanges be rejected with TA1? if yes, what error code should be used in TA105?
2. one interchange has more than one functional group. Should the whole interchange be rejected with TA1? or just 2nd and other groups in 999? what error codes should be used in either case?
3. one functional group has more than one transaction. Should the whole functional group be rejected with 999? or just 2nd and other transactions? what error codes should be used in either case?

Submitter Assigned Keywords

TA1 Error codes

Response

ASC X12 is not able to comment on the CORE requirements. The 005010X279 references a single patient request, there are no references to the ASC X12 control segments.

With regards to question 1. No, the second interchange should not be rejected using the TA1.

Question 2: No, the interchange should not be rejected with a TA1 and the functional group should not be rejected using a 999.

Question 3: No, the functional group and the transactions should not be rejected with a 999.

The scenarios stated in the request are not syntactical errors, they are business errors. As such, guide 005010X279 section 1.3.2 does provide instructions for related business situations. Please see the guide for the details.